CC Column Holder, stand alone, for 30mm CC Cartridges, ea.
Guard column dimension: 30 mm length, 4 mm ID Accessory for HPLC hardware: CC, stand alone Recommended application(s): HPLC Storage temperature: 15–25 °C / 59–77 °F Scope of delivery: 1x Guard column holder CC, incl. nuts and ferrules Gross weight (incl. packaging): 95 g / 0.21 lbs Packaging dimensions: 78 x 78 x 27 mm / 3.07 x 3.07 x 1.06 Inch Hazardous material: No
CC connecting Kit, ea.
Type Connection: Kit Packaging Quantity: 1 Kit Includes: 2 Nuts with End Fittings, Two Sleeves and Two Guide Rings For Use With: CC Column
Column Protection System Guard Column Holder
Guard column dimension: 4 mm length, 2 or 3 mm ID Accessory for HPLC hardware: EC, universal Recommended application(s): HPLC Storage temperature: 15–25 °C / 59–77 °F Scope of delivery: 1x Guard column holder, 3x Ferrules (for HPLC columns with particle size > 2 µm), 3x Ferrules (for HPLC columns with particle size < 2 µm), 2x double open ended wrenches (12 and 14 mm), 2x replacement capillaries (0.12 mm ID), 1x instruction leaflet Gross weight (incl. packaging): 223.1 g / 0.49 lbs Packaging dimensions: 165 x 95 x 55 mm / 6.50 x 3.74 x 2.17 Inch Hazardous material: No
HPTLC/TLC glass plates, modified silica gel layer, RP, Nano-SIL C18-50, 10x10 cm, 25 pc/PAK.
Method: Thin layer chromatography (HPTLC/TLC) Phase: Nano-SIL C18-50 Base material: Glass plates coated with silica gel Surface chemistry: Silica gel with octadecyl (C18, ODS, RP18) modification Mode: Reversed phase (RP) Plate size: 10x10 cm Layer thickness: 0.20 mm Layer hardness: Standard, soft UV indicator: No Support material / backing: Glass Particle size: 2–10 µm Particle type: Fully porous particles (FPP) Particle shape: Irregular Pore size: 60 Å Pore volume: 0.75 mL/g Binder: Yes pH stability: 2.0–10.0 Recommended application(s): Alkaloids, Amino acids, Barbiturates, Drugs, Flavonoids, Indole derivatives, Optical brighteners, Peptides, Phenols, Polycyclic aromatic hydrocarbons (PAH), Preservatives, Reversed phase, Steroids Temperature stability: High Storage temperature: 15–25 °C / 59–77 °F Scope of delivery: 25x HPTLC/TLC glass plates (10x10 cm) Gross weight (incl. packaging): 947 g / 2.09 lbs Packaging dimensions: 142 x 140 x 72 mm / 5.59 x 5.51 x 2.83 Inch Hazardous material: No
HPTLC/TLC glass plates, modified silica gel, RP, Nano-SIL C18-100 UV254, 10x10cm, 25 pc/PAK.
Method: Thin layer chromatography (HPTLC/TLC) Phase: Nano-SIL C18-100 UV254 Base material: Glass plates coated with silica gel Surface chemistry: Silica gel with octadecyl (C18, ODS, RP18) modification Mode: Reversed phase (RP) Plate size: 10x10 cm Layer thickness: 0.20 mm Layer hardness: Standard, soft UV indicator: Yes Support material / backing: Glass Particle size: 2–10 µm Particle type: Fully porous particles (FPP) Particle shape: Irregular Pore size: 60 Å Pore volume: 0.75 mL/g Binder: Yes pH stability: 2.0–10.0 Recommended application(s): Alkaloids, Amino acids, Barbiturates, Drugs, Flavonoids, Indole derivatives, Optical brighteners, Peptides, Phenols, Polycyclic aromatic hydrocarbons (PAH), Preservatives, Reversed phase, Steroids, Vegetable oils (identification of fatty oils acc. to EP). Temperature stability: High Storage temperature: 15–25 °C / 59–77 °F Scope of delivery: 25x HPTLC/TLC glass plates (10x10 cm) Gross weight (incl. packaging): 958 g / 2.11 lbs Packaging dimensions: 142 x 140 x 72 mm / 5.59 x 5.51 x 2.83 Inch Hazardous material: No
Nucleodur C18 ec, 110Å, 5µm, 4.0 x 125mm, ea.
Method: HPLC, analytical Brand: NUCLEODUR Base material: NUCLEODUR - high purity silica Phase: NUCLEODUR C18 ec 100-5 Surface chemistry: Medium density monomeric octadecyl (C18, ODS) modification Mode: Reversed phase (RP) Type: EC HPLC column (analytical) Hardware: Stainless steel Column length: 125 mm Column inner diameter: 4 mm Particle type: Fully porous particles (FPP) Particle shape: Spherical Particle size: 5 µm Eluent in HPLC column: Acetonitrile – water Recommended application(s): Aldehydes, Basic, neutral or acidic drugs, Derivatized amino acids, Fat-soluble vitamins, Ketones, Pesticides, Phenolic compounds, Reversed phase, RP applications HPLC Endcapped: Yes Carbon content: 17.5 % pH stability: 1.0–9.0 Pore size: 110 Å Specific surface according to BET: 340 m²/g Temperature stability (max): 60 °C Pressure stability (max): 600 bar / 8700 psi Column volume: 1.56 mL Storage temperature: 15–25 °C / 59–77 °F Scope of delivery: 1x analytical HPLC column, instruction leaflet, certificate of analysis Gross weight (incl. packaging): 188 g / 0.41 lbs Packaging dimensions: 115 x 235 x 50 mm / 4.53 x 9.25 x 1.97 Inch Hazardous material: No USP listing: L1
Nucleodur C18 Gravity, 110Å, 1.8µm, 4.6 x 30mm, ea.
Method: HPLC, analytical Brand: NUCLEODUR Base material: NUCLEODUR - high purity silica Phase: NUCLEODUR C18 Gravity Surface chemistry: Base deactivated (BDS), High density octadecyl (C18, ODS) modification Mode: Reversed phase (RP) Type: EC UHPLC column (analytical) Hardware: Stainless steel Column length: 30 mm Column inner diameter: 4.6 mm Particle type: Fully porous particles (FPP) Particle shape: Spherical Particle size: 1.8 µm Eluent in HPLC column: Acetonitrile – water Recommended application(s): Analgesics, Antidepressants, Antiinflammatory drugs, Applications at pH extremes (1-11), Herbicide, Ideal for method development, Immunosuppressants, Pharmaceuticals, Phytopharmaceuticals, Reversed phase, RP applications UHPLC Endcapped: Yes Carbon content: 18.0 % pH stability: 1.0–11.0 Pore size: 110 Å Specific surface according to BET: 340 m²/g Temperature stability (max): 60 °C Pressure stability (max): 900 bar / 13050 psi Column volume: 0.49 mL Storage temperature: 15–25 °C / 59–77 °F Scope of delivery: 1x analytical HPLC/UHPLC column, instruction leaflet, certificate of analysis Gross weight (incl. packaging): 117.93 g / 0.26 lbs Packaging dimensions: 235 x 117 x 54 mm / 9.25 x 4.61 x 2.13 Inch Hazardous material: No USP listing: L1
Nucleodur C18 Gravity, 110Å, 5µm, 4.6 x 250mm, ea
Method: HPLC, analytical Brand: NUCLEODUR Base material: NUCLEODUR - high purity silica Phase: NUCLEODUR C18 Gravity Surface chemistry: Base deactivated (BDS), High density octadecyl (C18, ODS) modification Mode: Reversed phase (RP) Type: EC HPLC column (analytical) Hardware: Stainless steel Column length: 250 mm Column inner diameter: 4.6 mm Particle type: Fully porous particles (FPP) Particle shape: Spherical Particle size: 5 µm Eluent in HPLC column: Acetonitrile – water Recommended application(s): Analgesics, Antidepressants, Antiinflammatory drugs, Applications at pH extremes (1-11), Herbicide, Ideal for method development, Immunosuppressants, Pharmaceuticals, Phytopharmaceuticals, Reversed phase, RP applications HPLC Endcapped: Yes Carbon content: 18.0 % pH stability: 1.0–11.0 Pore size: 110 Å Specific surface according to BET: 340 m²/g Temperature stability (max): 60 °C Pressure stability (max): 600 bar / 8700 psi Column volume: 4.15 mL Storage temperature: 15–25 °C / 59–77 °F Scope of delivery: 1x analytical HPLC column, instruction leaflet, certificate of analysis Gross weight (incl. packaging): 282.2 g / 0.62 lbs Packaging dimensions: 115 x 400 x 50 mm / 4.53 x 15.75 x 1.97 Inch Hazardous material: No USP listing: L1
Nucleodur C18 HTec, 110Å, 5µm, 4.6 x 250mm, ea.
Method: HPLC, analytical Brand: NUCLEODUR Base material: NUCLEODUR - high purity silica Phase: NUCLEODUR C18 HTec Surface chemistry: High density octadecyl (C18, ODS) modification, base deactivated (BDS) Mode: Reversed phase (RP) Type: EC HPLC column (analytical) Hardware: Stainless steel Column length: 250 mm Column inner diameter: 4.6 mm Particle type: Fully porous particles (FPP) Particle shape: Spherical Particle size: 5 µm Eluent in HPLC column: Acetonitrile – water Recommended application(s): Aldehydes, Applications at pH extremes (1-11), Basic, neutral and acidic pharmaceuticals, Derivatized amino acids, Fat-soluble vitamins, High loading capacity, Ketones, Pesticides, Phenolic compounds, Reversed phase, RP applications HPLC, Suitable for LC-MS Endcapped: Yes Carbon content: 18.0 % pH stability: 1.0–11.0 Pore size: 110 Å Specific surface according to BET: 340 m²/g Temperature stability (max): 60 °C Pressure stability (max): 600 bar / 8700 psi Column volume: 4.15 mL Storage temperature: 15–25 °C / 59–77 °F Scope of delivery: 1x analytical HPLC column, instruction leaflet, certificate of analysis Gross weight (incl. packaging): 231.67 g / 0.51 lbs Packaging dimensions: 405 x 117 x 54 mm / 15.94 x 4.61 x 2.13 Inch Hazardous material: No USP listing: L1
Nucleodur C18 Isis, 110Å, 3µm, 3.0 x 4mm, Guard Cartridge, pk.3
Method: HPLC, analytical Brand: NUCLEODUR Base material: NUCLEODUR - high purity silica Phase: NUCLEODUR C18 Isis Surface chemistry: High steric selectivity, Nonpolar crosslinked polymeric octadecyl (C18, ODS) modification Mode: Reversed phase (RP) Type: EC HPLC guard column (analytical) Hardware: Stainless steel Column length: 4 mm Column inner diameter: 3 mm Particle type: Fully porous particles (FPP) Particle shape: Spherical Particle size: 3 µm Eluent in HPLC column: Acetonitrile – water Recommended application(s): Guard column, ideal protection for your main column, HPLC Endcapped: Yes Carbon content: 20.0 % pH stability: 1.0–10.0 Pore size: 110 Å Specific surface according to BET: 340 m²/g Temperature stability (max): 60 °C Pressure stability (max): 600 bar / 8700 psi Storage temperature: 15–25 °C / 59–77 °F Scope of delivery: 3x analytical HPLC guard columns Gross weight (incl. packaging): 23 g / 0.05 lbs Packaging dimensions: 115 x 60 x 28 mm / 4.53 x 2.36 x 1.10 Inch Hazardous material: No USP listing: L1
Nucleodur C18 Isis, 110Å, 3µm, 4.0 x 150mm, ea.
Method: HPLC, analytical Brand: NUCLEODUR Base material: NUCLEODUR - high purity silica Phase: NUCLEODUR C18 Isis Surface chemistry: High steric selectivity, Nonpolar crosslinked polymeric octadecyl (C18, ODS) modification Mode: Reversed phase (RP) Type: EC HPLC column (analytical) Hardware: Stainless steel Column length: 150 mm Column inner diameter: 4 mm Particle type: Fully porous particles (FPP) Particle shape: Spherical Particle size: 3 µm Eluent in HPLC column: Acetonitrile – water Recommended application(s): (o,p,m-) Substituted aromatics, Exceptional steric selectivity, Fat-soluble vitamins, Reversed phase, RP applications HPLC, Steroids, Suitable for LC-MS Endcapped: Yes Carbon content: 20.0 % pH stability: 1.0–10.0 Pore size: 110 Å Specific surface according to BET: 340 m²/g Temperature stability (max): 60 °C Pressure stability (max): 600 bar / 8700 psi Column volume: 1.9 mL Storage temperature: 15–25 °C / 59–77 °F Scope of delivery: 1x analytical HPLC column, instruction leaflet, certificate of analysis Gross weight (incl. packaging): 163.5 g / 0.36 lbs Packaging dimensions: 235 x 117 x 54 mm / 9.25 x 4.61 x 2.13 Inch Hazardous material: No USP listing: L1
Nucleodur C8 Gravity, 110Å, 5µm, 4.6 x 150mm, ea.
Method: HPLC, analytical Brand: NUCLEODUR Base material: NUCLEODUR - high purity silica Phase: NUCLEODUR C8 Gravity Surface chemistry: Base deactivated (BDS), High density monomeric octyl (C8, MOS) modification Mode: Reversed phase (RP) Type: EC HPLC column (analytical) Hardware: Stainless steel Column length: 150 mm Column inner diameter: 4.6 mm Particle type: Fully porous particles (FPP) Particle shape: Spherical Particle size: 5 µm Eluent in HPLC column: Acetonitrile – water Recommended application(s): Analgesics, Antidepressants, Antiinflammatory drugs, Applications at pH extremes (1-11), Decreased retention of non-polar compounds, Herbicide, Ideal for method development, Immunosuppressants, Pharmaceuticals, Phytopharmaceuticals, RP applications HPLC, Similar to NUCLEODUR C18 Gravity, Suitable for LC-MS Endcapped: Yes Carbon content: 11.0 % pH stability: 1.0–11.0 Pore size: 110 Å Specific surface according to BET: 340 m²/g Temperature stability (max): 60 °C Pressure stability (max): 600 bar / 8700 psi Column volume: 2.5 mL Storage temperature: 15–25 °C / 59–77 °F Scope of delivery: 1x analytical HPLC column, instruction leaflet, certificate of analysis Gross weight (incl. packaging): 249.7 g / 0.55 lbs Packaging dimensions: 115 x 400 x 50 mm / 4.53 x 15.75 x 1.97 Inch Hazardous material: No USP listing: L7